Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/6742
metadata.dc.type: Artigo de Periódico
Título : RT-PCR for confirmation of echovirus 30 isolated in Belém, Brazil
Otros títulos : Brazilian Journal of Infectious Diseases
Autor : Gomes, Maria de Lourdes Contente
Ferreira, Lauze Lee Alves
Gomes, Rodrigo Henryque
Lamarão, Letícia Martins
Silveira, Edna da
Rodrigues, Lílian da Silva
Silva, Cláudio Ferreira da
Almeida, Eduardo Ribeiro de
metadata.dc.creator: Gomes, Maria de Lourdes Contente
Ferreira, Lauze Lee Alves
Gomes, Rodrigo Henryque
Lamarão, Letícia Martins
Silveira, Edna da
Rodrigues, Lílian da Silva
Silva, Cláudio Ferreira da
Almeida, Eduardo Ribeiro de
Resumen : Echovirus (Echo) 30 or human enterovirus B is the most frequent enterovirus associated with meningitis cases. Epidemics and outbreaks of this disease caused by Echo 30 have occurred in several countries. In Brazil, Echo 30 has been isolated from sporadic cases and outbreaks that occurred mainly in the south and southeast regions. We used RT-PCR to examine Echo 30 isolates from meningitis cases detected from March 2002 to December 2003 in Belém, state of Pará, in northern Brazil. The patients were attended in a Basic Health Unit (State Health Secretary of Pará), where cerebrospinal fluid (CSF) was collected and stored in liquid nitrogen. Weekly visits were made by technicians from Evandro Chagas Institute to the health unit and samples were stored at -70ºC in the laboratory until use. HEp-2 and RD cell lines were used for viral isolation and neutralization with specific antisera for viral identification. RNA extraction was made using Trizol reagent. The RT-PCR was made in one step, and the total mixture (50 µL) was composed of: RNA, reaction buffer, dNTP, primers, Rnase inhibitor, reverse transcriptase, Taq polymerase and water. The products were visualized in agarose gel stained with ethidium bromide, visualized under UV light. Among the 279 CSF samples examined, 30 (10.7%) were EV positive, 29 being Echo 30 and one was Cox B. Nineteen Echo 30 were examined with RT-PCR; 18 tested positive (762 and 494 base pairs). The use of this technique permitted viral identification in less time than usual, which benefits the patient and is of importance for public-health interventions.
Palabras clave : Echovirus 30
Aseptic meningitis
RT-PCR
Belém
Brazil
Editorial : The Brazilian Journal of Infectious Diseases and Contexto Publishing
URI : http://www.repositorio.ufba.br/ri/handle/ri/6742
Fecha de publicación : ago-2007
Aparece en las colecciones: Artigo Publicado em Periódico (Faculdade de Medicina)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Gomes, Maria de Lourdes C..pdf158,94 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.