Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5617
Tipo: Artigo de Periódico
Título: Development and validation of passive samplers for atmospheric monitoring of SO2, NO2, O3 and H2S in tropical areas
Título(s) alternativo(s): Microchemical Journal
Autor(es): Campos, Vânia Palmeira
Cruz, Lícia Passos dos Santos
Godoi, Ricardo H. M.
Godoi, Ana Flávia L.
Tavares, Tânia Mascarenhas
Autor(es): Campos, Vânia Palmeira
Cruz, Lícia Passos dos Santos
Godoi, Ricardo H. M.
Godoi, Ana Flávia L.
Tavares, Tânia Mascarenhas
Abstract: Traditionally the monitoring of atmospheric pollutants is aimed at managing accidents and short-term actions for the protection of human health on local and regional scales. These monitoring networks required continuous measurements with high time resolution, involving costly equipment, operation and maintenance. More recent simulations with mathematical models and scenario-building on regional, continental and global scales, as well as studies of environmental personal exposure are demanding three main types of monitoring design, where need for special resolution surpasses the one of temporal resolution: remote places, where no electric power nor trained human resources are available; validation of dispersion simulation by mathematical modeling on regional to larger scales; indoor measurements where people are acting under noise restriction such as residences, school and hospitals. To meet these demands environmental passive samplers for atmospheric gaseous pollutants have been developed and applied for different situations and environments of Brazil. Passive samplers were developed based on molecular diffusion of gas through a static layer of air with fixed filters impregnated with a specific solution for SO2, NO2, O3 and H2S and used in the following situations: in remote forest area, urban areas with different characteristics – near the sea, with clean ocean air masses coming in and in areas under direct industrial influence. The passive samplers showed good performance when exposed to different types of areas and during different periods: accuracy of measurements, based on standard deviation, were within the recommended limit by the European Union of ±25% for this type of device and precision below the maximum of 20% cited in the literature, with variation of 2.0 to 16% in the case of these work. The passive devices were able of measuring concentrations very low as those found in the Amazon region (0.58± 0.05 μg m−3 SO2 and 1.10±0.07 μg m−3 NO2) and higher concentrations in industrial areas (20.0±1.3 μg m−3 SO2 e 21.0±1.3 μgm−3 NO2).
Palavras-chave: Passive samplers
Sulfur dioxide
Nitrogen dioxide
Ozone
Atmospheric monitoring
URI: http://www.repositorio.ufba.br/ri/handle/ri/5617
Data do documento: 2010
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...12c67f5cad0293634feac70e91933.pdf
  Restricted Access
421,91 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.