Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5286
Tipo: Artigo de Periódico
Título: Influence of the parameters of the Er:YAG laser on the apical sealing of apicectomized teeth
Título(s) alternativo(s): Lasers in medical science
Autor(es): Marques, Aparecida Maria Cordeiro
Gerbi, Marleny Elizabeth M. M.
Santos, Jean Nunes dos
Noia, Manuela Pimentel
Oliveira, Priscila Chagas
Brugnera Júnior, Aldo
Zanin, Fátima Antonia Aparecida
Pinheiro, Antonio Luiz Barbosa
Autor(es): Marques, Aparecida Maria Cordeiro
Gerbi, Marleny Elizabeth M. M.
Santos, Jean Nunes dos
Noia, Manuela Pimentel
Oliveira, Priscila Chagas
Brugnera Júnior, Aldo
Zanin, Fátima Antonia Aparecida
Pinheiro, Antonio Luiz Barbosa
Abstract: Abstract Failures in the sealing of the tooth apex have been considered to be responsible for most of the failures of apical surgeries. The Er:YAG laser has been proposed as an alternative for the use of rotator instruments in surgical endodontics due to its precision, lack of vibration, less postoperative discomfort, bacterial reduction, and less stress for patients and professionals. Following approval by the ethics committee, 12 extracted human canines without previous endodontic treatment with anatomically normal roots and free from apical lesions were washed in running tap water and disinfected. The teeth were sectioned axially at the crown-root junction and submitted to routine endodontic treatment. The apical limit was set at 1 mm before the apical foramen. The root canals were routinely filled with Gutta-Percha points and Sealer 26 and were randomly distributed into two groups (n=6). In group I, apicectomy was performed with the Er:YAG laser (KAVO KEY Laser II®, Germany, =2.940 nm, pulsed mode, 2051 tip, with air spray cooling, 250 mJ/15 Hz). Apical cut was performed of perpendicular mode 3 mm from the apical foramen. In group II, the same procedures and the same sequence as above was used, varying only the parameters of the Er:YAG laser (400 mJ/6 Hz). Sealing of the cervical end the apex was carried out with acrylic resin; the roots were covered by a layer of epoxy glue and two layers of nail polish. The specimens were divided into groups and fixed, by the cervical third, on wax. Impermeabilization of the residual root apical third was performed following the same procedures used in the cervical third but the residual apex was left free from the impermeabilization. After that, the roots were immersed in a 2% methylene blue solution and placed in a bacteriological oven for 48 h and then washed in running tap water for 2 h. The samples were sagittally split into two parts. The segments were visually observed and the one showing the greatest level of dye leakage was selected and kept in an individual container and coded accordingly. Apical staining was measured using a stereoscopic magnifying glass, a compass, and a caliper. The measurement was performed by three endodontists,previously calibrated, and unaware of the sample coding. The results showed that group I showed the greatest level of dye leakage. There was a significantly difference between the groups (p=0.001). It is concluded that the apicectomies carried out with 400 mJ/6 Hz showed the smallest infiltration value.
Palavras-chave: Endodontic surgery
Leakage
Technique
URI: http://www.repositorio.ufba.br/ri/handle/ri/5286
Data do documento: 2011
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__www.springerlink.com_c...dv66813145h15553_fulltext.pdf
  Restricted Access
203,41 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.