Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/8445
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.contributor.authorJesus, Djane S. de-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCosta, Antonio Celso Spinola-
dc.creatorJesus, Djane S. de-
dc.date.accessioned2013-02-15T14:19:37Z-
dc.date.issued1996-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/8445-
dc.descriptionTexto completo: acesso restrito. p.1649–1656pt_BR
dc.description.abstractA major problem with spectrophotometric methods for nickel is cobalt interference, because many of the reagents for nickel also react with cobalt. In this work, the interference of cobalt in the determination of nickel using 2-(5-bromo-2-pyridylaxo)-5-diethylaminophenol (Br-PADAP) was eliminated by the use of derivative spectrophotometry, using the zero-crossing method for evaluation of the derivative signal. Br-PADAP reacts with nickel(II) in the presence of Triton X-100 to form a red complex with absorption maxima at 530 and 562 nm. The reactions parameters and the conditions for the measurements of the first-derivative signal were studied and the results demonstrated that using the derivative technique, Br-PADAP can be used for nickel determination with a selectivity higher than that of ordinary spectrophotometry and with a limit of detection of 0.2 ng ml−1. The pH should be in the range 5.0–6.0 using an acetate buffer. The determination of nickel in the presence of cobalt was performed with conventional and derivative procedures, and the results demonstrated that only the derivative method should be used and, of the methods used for evaluation of the derivative signal, the zero-crossing method is the best. The proposed procedure was used for nickel determination in steels standards. The results demonstrated that the procedure has satisfactory accuracy and precision. Cobalt interference can be also eliminated by using dual-wave-length spectroscopy.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org.ez10.periodicos.capes.gov.br/10.1016/0039-9140(96)01919-4pt_BR
dc.subjectBr-PADAPpt_BR
dc.subjectCobalt interferencept_BR
dc.subjectDerivative spectrophotometrypt_BR
dc.subjectNickelpt_BR
dc.titleDerivative spectrophotometric determination of nickel using Br-PADAPpt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 43, n. 10pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Ferreira.pdf
  Restricted Access
538,81 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.