Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7857
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorTeixeira, Leonardo Sena Gomes-
dc.contributor.authorRocha, Fábio Rodrigo Piovezani-
dc.contributor.authorKorn, Mauro-
dc.contributor.authorReis, Boaventura F.-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.creatorTeixeira, Leonardo Sena Gomes-
dc.creatorRocha, Fábio Rodrigo Piovezani-
dc.creatorKorn, Mauro-
dc.creatorReis, Boaventura F.-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCosta, Antonio Celso Spinola-
dc.date.accessioned2013-01-15T11:08:19Z-
dc.date.issued2000-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7857-
dc.descriptionTexto completo: acesso restrito. p. 1027–1033pt_BR
dc.description.abstractFlow-injection solid-phase spectrophotometry is applied for sequential determination of nickel and zinc, exploiting their different sorption rates on 1-(2-thiazolylazo)-2-naphthol (TAN) immobilized on C18-bonded silica. The Zn(II) sorption rate on the solid support is constant for flow rates ranging from 0.70 to 2.2 ml min−1, but for Ni(II) the sorption rate decreases with increasing flow rate. A flow system was designed to perform sequential measurements at two different flow rates (0.85 and 1.9 ml min−1). The absorbance was measured at 595 nm, where both TAN-immobilized complexes showed maximum absorption. The coefficients of variation were estimated (n=10) as 1.1 and 1.7% (at 1.9 ml min−1) and 1.2 and 2.1% (at 0.85 ml min−1) for zinc and nickel, respectively. This strategy was applied to determine zinc and nickel in copper-based alloys and the results agreed with certified values at the 95% confidence level. The sample throughput was estimated as 36 h−1.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0039-9140(00)00288-5pt_BR
dc.subjectSolid-phase spectrophotometrypt_BR
dc.subjectSorption ratespt_BR
dc.subjectFlow-injection analysispt_BR
dc.subjectNickelpt_BR
dc.subjectZincpt_BR
dc.subjectCopper-based alloyspt_BR
dc.titleNickel and zinc determination by flow-injection solid-phase spectrophotometry exploiting different sorption ratespt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 51, n. 5pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Teixeira.pdf
  Restricted Access
109,77 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.