Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7222
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorMacedo, Samuel Marques-
dc.contributor.authorSantos, Debora C. dos-
dc.contributor.authorJesus, Raildo M. de-
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorMacedo, Samuel Marques-
dc.creatorSantos, Debora C. dos-
dc.creatorJesus, Raildo M. de-
dc.creatorSantos, Walter Nei Lopes dos-
dc.date.accessioned2012-11-14T22:44:40Z-
dc.date.available2012-11-14T22:44:40Z-
dc.date.issued2011-
dc.identifier.issn0267-9477-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7222-
dc.descriptionp. 1887-1891pt_BR
dc.description.abstractThe present paper proposes an analytical procedure for speciation analysis of inorganic antimony in airborne particulate matter using slurry sampling and hydride generation atomic absorption spectrometry (HG QT AAS). During the antimony determination, a quartz T tube cell was heated to approximately 900 C using air–acetylene flame. The optimization step was performed by employing full two-level factorial and Box–Behnken designs involving the following factors: flow rate and concentration of sodium tetrahydroborate and hydrochloric acid concentration, having as chemometric response absorbance. Using the optimized conditions, the method employing slurry sampling allows for the determination of total Sb and Sb(III) with limits of quantification of 0.3 and 0.2 mg L 1, respectively. The precision, expressed as a relative standard deviation (%RSD), was always lower than 6.2%. The accuracy was confirmed by analysis of a certified reference material of atmospheric particulate matter urban dust furnished by National Institute of Standards & Technology. This method was used to determine total antimony and antimony(III) in four particulate matter samples collected in Bananeira Village, Bahia State, Brazil. In these samples, total antimony concentrations varied from 4.32 to 4.60 ng m 3, and Sb(III) concentrations varied from 0.33 to 0.67 ng m 3.pt_BR
dc.description.sponsorshipFAPESB; CNPq; CAPESpt_BR
dc.language.isoen_USpt_BR
dc.sourcehttp://pubs.rsc.org/en/content/articlepdf/2011/JA/C1JA10108Kpt_BR
dc.titleSpeciation analysis of inorganic antimony in airborne particulate matter employing slurry sampling and HG QT AASpt_BR
dc.title.alternativeJournal of Analytical Atomic Spectrometrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.number26pt_BR
Aparece nas coleções:Artigo Publicado em Periódico (POSPETRO)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Speciation analysis of inorganic antimony in airborne particulate matter.pdfartigo 2011161,09 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.