Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7153
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorPinheiro, Heloísa Lúcia C.-
dc.contributor.authorAndrade, Marta Valéria Almeida Santana de-
dc.contributor.authorPereira, Pedro Afonso de Paula-
dc.contributor.authorAndrade, Jailson Bittencourt de-
dc.creatorPinheiro, Heloísa Lúcia C.-
dc.creatorAndrade, Marta Valéria Almeida Santana de-
dc.creatorPereira, Pedro Afonso de Paula-
dc.creatorAndrade, Jailson Bittencourt de-
dc.date.accessioned2012-11-08T19:01:53Z-
dc.date.issued2004-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7153-
dc.descriptionp. 15-20pt_BR
dc.description.abstractIn the present work, a sensitive and selective fluorimetric method for formaldehyde determination in air samples is described. The method is based in the reaction between formaldehyde and Fluoral P producing 3,5-diacetyl-1,4-dihydrolutidine, which, when excited at 410 nm,emits fluorescence at 510 nm.The Fluoral P was prepared by the reaction of 0.3 ml of acetic acid, 0.2 ml of acetylacetone and 15.4 g of ammonium acetate. Then, the volume was completed to 100 ml with deionized water. The Fluoral P obtained, if stored under refrigeration in the dark, can be used, safely,for 60 days.The calibration curve obtained with concentrations of formaldehyde in the range of 12 to 192 ng ml 1 (n=9) was Intensity=1.11C+0.06(R2=0.9920). In the quantification of formaldehyde, air samples were passed at 1 l min 1, during 120 min, through glass impingers containing 40 ml of Fluoral P, followed by direct fluorescence measuring, or through two SEP PAK silica cartridges, coated with Fluoral P. The cartridges were eluted with 10 ml of Fluoral P solution and quantified by spectrofluorimetry. Under these conditions, the detection limit(S/N=3) obtained was 2.0 ng ml 1.The new methodology was validated by comparison with a well-known HPLC method in which formaldehyde was collected into SEP PAK C18 cartridges coated with 2,4 dinitrophenylhydrazine. The application of the t95% test did not show significant differences between theHPLC and either fluorimetric methodologies.This method has been used in the determination of gas phase formaldehyde in both indoor and outdoor sites. For the indoor site, the measured concentrations were in the range of 9.0 to 67.7 Al l 1, while for the outdoor site they were in the range of 16.8 to 38.8 Al l 1. Further, due to the ease of handling in field studies, the SEP PAK cartridges coated with Fluoral P were used. The formaldehyde concentrations thus determined, in outdoor sites, were in the range of 2.09 to 25.1 Al l 1. The main advantage of this analytical procedure is its selectivity for formaldehyde, without interferences from bisulfite and other aldehydes, especially acetaldehyde, and low blank level, resulting in low detection limits. In addition, very little sample preparation is required.pt_BR
dc.language.isoenpt_BR
dc.publisherElsevierpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.microc.2004.02.017,pt_BR
dc.subjectFormaldehydept_BR
dc.subjectAir samplingpt_BR
dc.subjectSpectrofluorimetrypt_BR
dc.titleSpectrofluorimetric determination of formaldehyde in air after collection onto silica cartridges coated with Fluoral Ppt_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 78, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S0026265X0400061X-main.pdf
  Restricted Access
227,51 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.