Use este identificador para citar ou linkar para este item:
https://repositorio.ufba.br/handle/ri/6601
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Soylak, Mustafa | - |
dc.contributor.author | Narin, Ibrahim | - |
dc.contributor.author | Bezerra, Marcos de Almeida | - |
dc.contributor.author | Ferreira, Sergio Luis Costa | - |
dc.creator | Soylak, Mustafa | - |
dc.creator | Narin, Ibrahim | - |
dc.creator | Bezerra, Marcos de Almeida | - |
dc.creator | Ferreira, Sergio Luis Costa | - |
dc.date.accessioned | 2012-08-17T19:09:21Z | - |
dc.date.issued | 2005-02-28 | - |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.uri | http://www.repositorio.ufba.br/ri/handle/ri/6601 | - |
dc.description | Trabalho completo: acesso restrito, p. 895–899 | pt_BR |
dc.description.abstract | The present paper proposes a preconcentration procedure for lead determination using flame atomic absorption spectrometry (FAAS). It is based on lead(II) ions extraction as brilliant cresyl blue (BCB) complex and its sorption onto Diaion HP-2MG, a methacrylic ester copolymer. The optimization step was carried out using factorial design and the variables studied were pH, shaking time and reagent concentration. In the established experimental conditions, lead can be determinate with a limit of detection of 3.7 μg L−1 lead (N = 20) and a relative standard deviation of 7% for a lead concentration of 100 μg L−1. The accuracy was confirmed by analysis of a certified reference material, the stream sediment furnished by National Research Centre for Certified Reference Materials (NRCCRM), China (GBW 07310). Effect of other ions in the procedure proposed was also studied. The method was applied for lead determination in real samples of water, tea, soil and dust. Tests of addition/recovery in the experiments for lead determination in water samples revealed that the proposed procedure could be applied satisfactorily for analysis of these samples. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.source | http://dx.doi.org/10.1016/j.talanta.2004.08.011 | pt_BR |
dc.subject | Preconcentration | pt_BR |
dc.subject | Lead | pt_BR |
dc.subject | Factorial Design | pt_BR |
dc.subject | FAAS | pt_BR |
dc.title | Factorial design in the optimization of preconcentration procedure for lead determination by FAAS | pt_BR |
dc.title.alternative | Talanta | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.identifier.number | v. 65, n. 4 | pt_BR |
dc.embargo.liftdate | 10000-01-01 | - |
Aparece nas coleções: | Artigo Publicado em Periódico (Química) |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
(166).pdf Restricted Access | 120,14 kB | Adobe PDF | Visualizar/Abrir Solicitar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.