Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6480
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.contributor.authorSilva, Erik Galvão Paranhos da-
dc.contributor.authorFernandes, Marcelo Santiago-
dc.contributor.authorAraujo, Rennan Geovanny Oliveira-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.creatorSantos, Walter Nei Lopes dos-
dc.creatorSilva, Erik Galvão Paranhos da-
dc.creatorFernandes, Marcelo Santiago-
dc.creatorAraujo, Rennan Geovanny Oliveira-
dc.creatorCosta, Antonio Celso Spinola-
dc.date.accessioned2012-07-20T15:19:31Z-
dc.date.issued2005-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6480-
dc.descriptionTrabalho completo: acesso restrito, p. 1099–1102pt_BR
dc.description.abstractChocolate is a complex sample with a high content of organic compounds and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. The determination of copper in chocolate is important because copper compounds are extensively used as fungicides in the farming of cocoa. In this paper, a slurry-sampling flame atomicabsorption spectrometric method is proposed for determination of copper in powdered chocolate samples. Optimization was carried out using univariate methodology involving the variables nature and concentration of the acid solution for slurry preparation, sonication time, and sample mass. The recommended conditions include a sample mass of 0.2 g, 2.0 mol L 1 hydrochloric acid solution, and a sonication time of 15 min. The calibration curve was prepared using aqueous copper standards in 2.0 mol L 1 hydrochloric acid. This method allowed determination of copper in chocolate with a detection limit of 0.4 lg g 1 and precision, expressed as relative standard deviation (RSD), of 2.5% (n=10) for a copper content of approximately 30 lg g 1, using a chocolate mass of 0.2 g. The accuracy was confirmed by analyzing the certified reference materials NIST SRM 1568a rice flour and NIES CRM 10-b rice flour. The proposed method was used for determination of copper in three powdered chocolate samples, the copper content of which varied between 26.6 and 31.5 lg g 1. The results showed no significant differences with those obtained after complete digestion, using a t-test for comparison.pt_BR
dc.language.isoenpt_BR
dc.publisherSpringer Verlagpt_BR
dc.sourcehttp://www.springerlink.com/content/n86182457l465jv6/fulltext.pdfpt_BR
dc.subjectslurry-samplingpt_BR
dc.subjectFAASpt_BR
dc.subjectCopperpt_BR
dc.subjectChocolatept_BR
dc.titleDetermination of copper in powdered chocolate samples by slurry-sampling flame atomic-absorption spectrometrypt_BR
dc.title.alternativeAnalytical and Bioanalytical Chemistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 382, n. 4pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
(131).pdf
  Restricted Access
192,81 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.