Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6352
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorTeixeira, Leonardo Sena Gomes-
dc.contributor.authorOliveira, Fábio Santos de-
dc.contributor.authorSantos, Hilda Costa dos-
dc.contributor.authorCordeiro, Paulo Wilson Louzado-
dc.contributor.authorAlmeida, Selmo Q.-
dc.creatorTeixeira, Leonardo Sena Gomes-
dc.creatorOliveira, Fábio Santos de-
dc.creatorSantos, Hilda Costa dos-
dc.creatorCordeiro, Paulo Wilson Louzado-
dc.creatorAlmeida, Selmo Q.-
dc.date.accessioned2012-07-06T11:59:52Z-
dc.date.issued2008-
dc.identifier.issn0013-7227-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6352-
dc.descriptionAcesso restrito: Texto completo. p. 1399-1406pt_BR
dc.description.abstractIn the present work, Fourier transform infrared spectroscopy (FTIR) in association with multivariate chemometrics classification techniques was employed to identify gasoline samples adulterated with diesel oil, kerosene, turpentine spirit or thinner. Results indicated that partial least squares (PLS) models based on infrared spectra were proven suitable as practical analytical methods for predicting adulterant content in gasoline in the volume fraction range from 0% to 50%. The results obtained by PLS provided prediction errors lower than 2% (v/v) for all adulterant determined. Additionally, Soft Independent Modeling of Class Analogy (SIMCA) was performed using all spectral data (650–3700 cm 1) for sample classification into adulterant classes defined by training set and the results indicated that undoubted adulteration detection was possible but identification of the adulterant was subject to misclassification errors, specially for kerosene and turpentine adulterated samples, and must be carefully examined. Quality control and police laboratories for gasoline analysis should employ the proposed methods for rapid screening analysis for qualitative monitoring purposes.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.fuel.2007.05.016pt_BR
dc.subjectGasoline adulterationpt_BR
dc.subjectSIMCA modelpt_BR
dc.subjectPLS analysispt_BR
dc.titleMultivariate calibration in Fourier transform infrared spectrometry as a tool to detect adulterations in Brazilian gasolinept_BR
dc.title.alternativeEndocrinologypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 149, n. 3pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
CONFIG~1...-S0016236107002256-main-1.pdf
  Restricted Access
1,28 MBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.