Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6036
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Josué Carinhanha Caldas-
dc.contributor.authorSantos, Eduardo Batista Guimarães Nunes-
dc.contributor.authorKorn, Mauro-
dc.creatorSantos, Josué Carinhanha Caldas-
dc.creatorSantos, Eduardo Batista Guimarães Nunes-
dc.creatorKorn, Mauro-
dc.date.accessioned2012-05-31T19:46:44Z-
dc.date.issued2008-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6036-
dc.descriptionAcesso restrito: Texto completo. p. 1-7pt_BR
dc.description.abstractIn the present work a systematic comparison among spectrophotometric flow injection methods for sulfide determination based on phenothiazine dye production from diverse aromatic p-substituted amines were performed. The behavior of N,N-dimethylphenyl-p-diamine (DMPD), N,N-diethylphenyl-p-diamine (DEPD), phenyl-p-diamine (PPD), p-aminophenol (PAP) and other three aromatic amines was investigated and the chemical parameters of proposed flow methods were optimized by applying central composite design. For each evaluated method the concentration of amine, Fe3+ and H2SO4 was optimized and after the evaluation of reagents addition order the flow parameters were independently ascertained. Analytical signal was strongly diminished in the presence of iodide for flow methods based on the reaction of sulfide with DMPD, PPD or DEPD while fluoridewas considered as an important interference for methods based on the reaction with PPD or PAP. The evaluated aromatic amines have permitted sulfide determination in a wide concentration range from 0.05 to 3.0 mg L−1 and limits of detection (3σ) varying from 18.8 to 51.0 μg L−1, for DEPD and PPD, respectively. The sensitivity of flow methods based on PPD and DMPD was higher even as PAP has permitted sulfide determination in a large sulfide concentration range. In addition, higher throughput was attained for DMPD method. The proposed methods were applied for sulfide determination in industrial wastewater and the obtained results were in agreement with reference method at 95% confidence level.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.microc.2008.02.007pt_BR
dc.subjectSulfide determinationpt_BR
dc.subjectAromatic p-substituted aminespt_BR
dc.subjectFaced composite central designpt_BR
dc.subjectFlow injection analysispt_BR
dc.subjectWastewater analysispt_BR
dc.titleA comparison of flow injection methods for sulfide determination based on phenothiazine dyes produced from diverse aromatic aminespt_BR
dc.title.alternativeMICROCHEMICAL JOURNALpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 90, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...85453f62e887f15fe34a6ab349ab9.pdf
  Restricted Access
401,47 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.