Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5622
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorMacedo, Samuel Marques-
dc.contributor.authorSantos, Debora C. dos-
dc.contributor.authorJesus, Raildo M. de-
dc.contributor.authorRocha, Gisele Olímpio da-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorAndrade, Jailson Bittencourt de-
dc.creatorMacedo, Samuel Marques-
dc.creatorSantos, Debora C. dos-
dc.creatorJesus, Raildo M. de-
dc.creatorRocha, Gisele Olímpio da-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorAndrade, Jailson Bittencourt de-
dc.date.accessioned2012-04-13T13:37:01Z-
dc.date.issued2010-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/5622-
dc.descriptionAcesso restrito: Texto completo. p. 46-49.pt_BR
dc.description.abstractSlurry sampling (SS) with hydride generation atomic absorption spectrometry (HG-AAS) was used to analyze 3 particulate matter samples collected in the Bananeira Village, Brazil, in 2005. The relative standard deviation (RSD), used to assess the precision, was lower than 4.8%. The accuracy of this method was confirmed by the analysis of certified atmospheric particulate matter urban dust reference material SRM 1649a. This method (SS/HG-AAS) was used to determine total arsenic and arsenic (III) in three particulate matter samples. In these samples, the total arsenic concentrations varied from 3.8 to 20.0 ng m−3, while As (III) concentrations varied from 2.7 to 10.5 ng m−3. All samples were also analyzed using acid digestion in digest block with cold finger and detection for HG-AAS. A paired t-test demonstrated no significant difference (95% CL) between the results obtained using these two sample preparation procedures. The limit of quantification, calculated considering themass of particulate matter collected on every filter, was 0.6 ng m−3 for As total and 1.0 ng m−3 for As (III).pt_BR
dc.language.isoenpt_BR
dc.sourceDOI: 10.1016/j.microc.2010.01.019pt_BR
dc.subjectSlurry samplingpt_BR
dc.subjectAtmospheric particulate matterpt_BR
dc.subjectArsenicpt_BR
dc.subjectHydride generation atomic absorption spectrometrypt_BR
dc.titleDevelopment of an analytical approach for determination of total arsenic and arsenic (III) in airborne particulate matter by slurry sampling and HG-FAASpt_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 96, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...17a4a632f2f689cc7578e1d4647a3.pdf
  Restricted Access
125,78 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.