Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5479
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorPortugal, Lindomar Andrade-
dc.contributor.authorMatos, Geraldo D.-
dc.contributor.authorLima, Daniel C.-
dc.contributor.authorBrito, Geysa Barreto-
dc.contributor.authorFernandes, Andréa Pires-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorPortugal, Lindomar Andrade-
dc.creatorMatos, Geraldo D.-
dc.creatorLima, Daniel C.-
dc.creatorBrito, Geysa Barreto-
dc.creatorFernandes, Andréa Pires-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2012-03-01T13:21:10Z-
dc.date.issued2011-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/5479-
dc.descriptionAcesso restrito: Texto completo. p. 29-31.pt_BR
dc.description.abstractThis paper proposes a method for the determination of lead in aluminum and magnesium antacids employing electrothermal atomic absorption spectrometry (ET AAS). The pyrolysis and atomization temperatures established during the optimization step were 700 and 2200 °C, respectively, using phosphate as the chemical modifier. Under these conditions, a characteristic mass of 25 pg, and limits of detection and quantification of 0.40 and 1.35 μg L−1, respectively were obtained. Some experiments demonstrated that the calibration can be performed employing the external calibration technique using aqueous standards. The precision expressed as relative standard deviation (RSD %) was 4.03% for an antacid sample with lead concentrations of 284.5 μg L−1. The proposed method was applied for the determination of lead in five antacid samples acquired in Salvador City, Brazil. The lead content was varied from 87 to 943 μg g−1. The samples were also analyzed after complete dissolution by inductively coupled plasma mass spectrometry (ICP-MS). No statistical difference was observed between the results obtained by both of the procedures performed.pt_BR
dc.language.isoenpt_BR
dc.sourceDOI: 10.1016/j.microc.2010.10.005pt_BR
dc.subjectLead determinapt_BR
dc.subjectAntacid samplespt_BR
dc.subjectET AASpt_BR
dc.titleDetermination of lead in aluminum and magnesium antacids using electrothermal atomic absorption spectrometrypt_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 98, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__pdn.sciencedirect.com.....0-S0026265X10002110-main.pdf
  Restricted Access
99,19 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.