Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5279
Tipo: Artigo de Periódico
Título: Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling
Título(s) alternativo(s): Elsevier
Autor(es): Borges, Aline Rocha
Becker, Emilene M.
Lequeux, Céline
Vale, Maria Goreti R.
Ferreira, Sergio Luis Costa
Welz, Bernhard
Autor(es): Borges, Aline Rocha
Becker, Emilene M.
Lequeux, Céline
Vale, Maria Goreti R.
Ferreira, Sergio Luis Costa
Welz, Bernhard
Abstract: The determination of cadmium (Cd) in fertilizers is of major interest, as this element can cause growth problems in plants, and also affect animals and humans. High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with charge-coupled device (CCD) array detection overcomes several of the limitations encounteredwith conventional line source AAS, especially the problem of accurate background measurement and correction. In this work an analytical method has been developed to determine Cd in fertilizer samples by HR-CS GF AAS using slurry sampling. Both a mixture of 10 μg Pd+6 μg Mg in solution and 400 μg of iridium as permanent modifier have been investigated and aqueous standards were used for calibration. Pyrolysis and atomization temperatures were 600 °C and 1600 °C for the Pd-Mg modifier, and 500 °C and 1600 °C for Ir, respectively. The results obtained for Cd in the certified referencematerial NIST SRM695 (Trace Elements in Multi-Nutrient Fertilizer) of 16.7±1.3 μg g−1 and 16.4±0.75 μg g−1 for the Pd–Mg and Ir modifier, respectively, were statistically not different from the certified value of 16.9±0.2 μg g−1 on a 95% confidence level; however, the results obtained with the Ir modifier were significantly lower than those for the Pd–Mg modifier for most of the samples. The characteristic mass was 1.0 pg for the Pd–Mg modifier and 1.1 pg Cd for the Ir modifier, and the correlation coefficients (R2) of the calibration wereN0.99. The instrumental limits of detection were 7.5 and 7.9 ng g−1, and the limits of quantification were 25 and 27 ng g−1 for Pd–Mg and Ir, respectively, based on a sample mass of 5 mg. The cadmium concentration in the investigated samples was between 0.07 and 5.5 μg g−1 Cd, and hence below the maximum value of 20 μg g−1 Cd permitted by Brazilian legislation.
Palavras-chave: High-resolution continuum source graphite
furnace atomic absorption spectrometry
Cadmium determination
Slurry sampling
Fertilizer analysis
Modifiers
URI: http://www.repositorio.ufba.br/ri/handle/ri/5279
Data do documento: Abr-2011
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.