Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/36643
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCruz, Lícia Passos dos Santos-
dc.date.accessioned2023-02-27T11:17:51Z-
dc.date.available2023-02-27T11:17:51Z-
dc.date.issued2007-03-30-
dc.identifier.citationCRUZ, Lícia Passos dos Santos. Desenvolvimento e validação de amostradores passivos para o monitoramento de poluentes atmosféricos. 2007. 220 f. Tese (Doutorado em Química) Instituto de Química, Universidade Federal da Bahia, Salvador, Ba, 2007.pt_BR
dc.identifier.urihttps://repositorio.ufba.br/handle/ri/36643-
dc.description.abstractPassive samplers are devices capable of taking samples of gas or vapor pollutants from the atmosphere without involving air active movement through them. The sampling rate is controlled by a physical process such as diffusion or permeation. The objective of this work was to develop and to validate passive samplers for the monitoring of NO2, O3, SO2 and H2S in outdoor environments aiming to cooperate with the growing of the spatial resolution and efficiency of atmospheric monitoring networks. The model of the used passive sampler was based on gas molecular diffusion through static air layer and consists of a cylindrical polyethylene tube (internal diameter 21 mm, length 12 mm) sealed at the bottom. To minimize turbulent diffusion and particle interference a stainless steel screen and Teflon membrane were used in the air inlet. After diffusion layer there was a cellulose filter which was impregnated with a specific reagent to trap the diffused gas. After exposure of the samplers the trapped gas in the form of the product reaction was extracted in an ultrasonic bath for 15 min. The absorbed SO2 as sulfite in the filter containing with 1.0 x 10-2 mol L-1 Na2CO3 was extracted with 1.5 mL of 1.0 x 10-2 mol L -1 H2O2 solution to ensure complete oxidation to sulfate, which was later determined by ion chromatography. The O3 reacted with nitrite ion of the impregnating solution (1.5 x 10-1 mol L -1 NaNO2 / 2.0 x 10-1 mol L-1 Na2CO3 / 1.0 mol L-1 glycerol) to produce nitrate ion, which was extracted with 1.5 mL of deionized water and also determined by ion chromatography. The absorbed NO2 in the impregnated filter with 5.0 x 10-1 mol L-1 KI / 2.0 x 10-1 mol L-1 KOH in methanol was extracted with deionized water and determined as NO2 - by UV-Vis molecular spectrophotometry. The trapped H2S in the impregnated filter with 5.5 x10-2 mol L-1 zinc acetate / 1.0 x 10-1 mol L-1 NaOH / 1.0 x 10-2 mol L-1 trisodic citrate was determined as sulfide by UV-Vis molecular spectrophotometry. The performance of the passive samplers was evaluated during exposure periods of 1 to 4 weeks in industrial influence areas next to the Industrial Complex of Camaçari-BA and urban area (Salvador-BA) as well as site presently used as pasture (former forest) in the Amazon region and petroleum fields (Buracica-BA). The precision of the measurements as relative standard deviation according to the obtained results from the simultaneously applied passive samplers varied between 2.4 and 12% for SO2, 2.0 and 15% for NO2, 2.5 and 16% for O3, 5.2 and 15% for H2S, in the following concentration levels ranging: 0.58 - 20 µg m-3 SO2, 1.1 - 21 g m-3 NO2, 14 - 51 g m-3 O3 and 0.40 - 3.0 µg m-3 H2S. The average accuracy (10 - 19%) was determined by comparison with simultaneous parallel measurements that were carried out with calibrated continuous monitors in industrial and pasture areas, and with diffusion tubes (denuder) in urban and pasture areas.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa da Bahia (Fapesb); Financiadora de Estudos e Projetos (FINEP); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq);pt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Bahiapt_BR
dc.subjectAmostragem passivapt_BR
dc.subjectDióxido de enxofrept_BR
dc.subjectDióxido de nitrogêniopt_BR
dc.subjectOzôniopt_BR
dc.subjectSulfeto de hidrogêniopt_BR
dc.subjectMonitoramento ambientalpt_BR
dc.subject.otherPassive samplingpt_BR
dc.subject.otherSulfur dioxidept_BR
dc.subject.otherNitrogen dioxidept_BR
dc.subject.otherOzonept_BR
dc.subject.otherHydrogen sulfidept_BR
dc.subject.otherEnvironment monitoringpt_BR
dc.titleDesenvolvimento e validação de amostradores passivos para o monitoramento e poluentes atmosféricospt_BR
dc.title.alternativeDevelopment and validation of passive samplers for the monitoring of air pollutantspt_BR
dc.typeTesept_BR
dc.publisher.programPrograma de Pós-Graduação em Química pt_BR
dc.publisher.initialsUFBApt_BR
dc.publisher.countryBrasilpt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::ANALISE DE TRACOS E QUIMICA AMBIENTALpt_BR
dc.contributor.advisor1Campos, Vania Palmeira-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1899788512240970pt_BR
dc.contributor.referee1Godoi, Ana Flávia Locateli-
dc.contributor.referee1ID0000-0003-1188-6751pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/3922741598561613pt_BR
dc.contributor.referee2Martins, Ayrton Figueiredo-
dc.contributor.referee2ID0000-0002-8931-7877pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2113532494494821pt_BR
dc.contributor.referee3Botelho, Maria de Lourdes Mascarenhas Figueiredo-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/7935197779073963pt_BR
dc.contributor.referee4Ferreira, Sergio Luiz Costa-
dc.contributor.referee4ID0000-0001-7738-045Xpt_BR
dc.contributor.referee4Latteshttp://lattes.cnpq.br/9198426685541534pt_BR
dc.contributor.referee5Campos, Vania Palmeira-
dc.contributor.referee5Latteshttp://lattes.cnpq.br/1899788512240970pt_BR
dc.creator.ID0000-0003-4455-9116pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/5729616844568212pt_BR
dc.description.resumoAmostradores passivos são dispositivos capazes de fixar gases ou vapores atmosféricos a uma taxa controlada por um processo físico, como difusão ou permeação, não envolvendo o uso de bomba de sucção. O objetivo deste trabalho foi desenvolver e validar amostradores passivos para aplicação no monitoramento de NO2, O3, SO2 e H2S em ambientes externos, visando colaborar com o aumento da resolução espacial e eficiência de redes de monitoramento atmosférico. O modelo do amostrador passivo utilizado baseia-se em difusão molecular do gás através de uma camada estática de ar e consiste de um corpo cilíndrico de polietileno (12 mm de altura e 21 mm de diâmetro interno), fechado no fundo, com uma tela de aço inox e uma membrana de Teflon na entrada do ar para minimizar a turbulência e interferência de partículas. No final do percurso de difusão encontra-se um filtro de celulose impregnado com reagente específico para fixar o gás difundido. Após o período de exposição dos amostradores, o gás fixado na forma do produto da reação foi extraído em ultrassom por 15 min. O SO2 absorvido como sulfito no filtro impregnado com Na2CO3 1,0 x 10-2 mol L-1 foi extraído utilizando-se 1,5 mL de H2O2 1,0 x 10-2 mol L -1 para garantir completa oxidação a sulfato, e este foi posteriormente determinado por cromatografia iônica. O ozônio reage com o íon nitrito da solução de impregnação (NaNO2 1,5 x 10-1 mol L-1 / Na2CO3 2,0 x 10-1 mol L-1 / glicerol 1,0 mol L-1 ) para produzir o íon nitrato, sendo este extraído com 1,5 mL de água deionizada e determinado também por cromatografia iônica. O NO2 absorvido no filtro impregnado com KI 5,0 x 10-1 mol L -1 / KOH 2,0 x 10-1 mol L-1 em metanol foi extraído com água deionizada e determinado como NO2 - por espectrofotometria molecular UV-Vis. O H2S fixado no filtro impregnado com acetato de zinco 5,5 x 10-2 mol L-1 / NaOH 1,0 x 10-1 mol L-1 / citrato trisódico 1,0 x 10-2 mol L-1 foi determinado como sulfeto por espectrofotometria molecular UV-Vis. O desempenho dos amostradores passivos foi avaliado durante períodos de exposição de 1 a 4 semanas em áreas de influência industrial próximas ao Pólo Industrial de Camaçari-BA, área urbana (Salvador-BA), de floresta transformada em pasto (região Amazônica) e em campo de exploração de petróleo (Buracica-BA). A precisão das medidas, expressa como desvio padrão relativo dos resultados obtidos com os amostradores expostos simultaneamente, variou de 2,4 a 12% para SO2, de 2,0 a 15% para NO2, de 2,5 a 16% para O3 e de 5,2 a 15% para H2S, nas seguintes faixas de concentração: 0,58 - 20 µg m-3 de SO2, 1,1 - 21 µg m-3 de NO2, 14 - 51 µg m-3 de O3 e 0,40 - 3,0 µg m-3 de H2S. A exatidão média (10 a 19%) foi determinada por comparação com medidas simultâneas paralelas realizadas com monitores contínuos calibrados em área industrial e de floresta transformada em pasto, e com tubos de difusão (denuder) em área urbana e de pastopt_BR
dc.publisher.departmentInstituto de Químicapt_BR
dc.type.degreeDoutoradopt_BR
Aparece nas coleções:Tese (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Tese_Licia_Passos_2007.pdfTese de Doutorado de Lícia Passos dos Santos Cruz9,02 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.